A New Standard in Brain Tissue Processing
Introducing the LeviSelect™ Complete Mouse Myelin Depletion Kit, a complete solution that combines tissue dissociation, red blood cell depletion and myelin removal in a single streamlined workflow. Get ready to supercharge your neural studies like never before.

- Built to scale
Ready for automated, 96-well workflows
Brain studies need consistent inputs across many animals, regions and time points. The LeviCell 96 runs label-free enrichment alongside targeted depletion for up to 96 samples per run on standard SBS-compatible robotics, giving you higher-quality inputs, more samples per day and a lower cost per sample.
- Combined in one run: depletion, viable cell enrichment and debris removal
- Consistent well to well, without manual variability
- High-fidelity data for large-scale studies
All-in-One Brain Tissue Prep for Better Results
The LeviSelect Complete Mouse Myelin Depletion Kit delivers high-performance results, even from small sample inputs (up to 25 mg). Whether you’re working with precious brain segments or need to prep multiple samples quickly, LeviSelect is built to your exacting needs.
- Cold tissue dissociation + myelin + RBC depletion in one kit
- Optimized for low-input brain tissue
- Fully compatible with Levitation Technology
- Supports scRNA-Seq and other downstream assays
Why Replace Traditional Density Gradient Approaches?
| Feature | Traditional (Percoll) | Levitation Technology |
|---|---|---|
| Workflow | Multi-step density gradient | Dissociate, then one 3-step LeviCell run |
| Cell yield | Lower | >2× higher |
| Cell viability | ~70% | >95% |
| Sample input | High | Low (10–25 mg) |
| Scalability | Limited | Scalable, 1 to 96 samples |
Ditch the gradients. Choose a gentler, faster, and more consistent prep for your brain samples.
Simple, proven workflow: dissociate, then levitate
Complete your prep in about 2 hours with only 30 minutes of hands-on time. Stage 1 is cold tissue dissociation with the kit reagents. Stage 2 is a standard three-step LeviCell run (load, levitate, collect) that depletes myelin and RBCs while enriching viable cells in a single levitation.
We are pretty happy with the myelin removal and clean-up and are very interested in pursuing a strategy to enrich our target cells.
— Customer evaluation, mouse hippocampus study
Who Is This Kit For?
LeviSelect is ideal for researchers who:
- Need a full solution from dissociation to assay-ready cells
- Work with limited or precious mouse brain samples
- Struggle with low yields or myelin/RBC contamination
- Perform downstream assays like single-cell RNA sequencing
Ordering info
The LeviSelect™ Complete Mouse Myelin Depletion Kit is available for ordering now. Contact your local representative or click below to get started.
Depletion Kits
LeviSelect™ Complete Mouse Myelin Depletion Kit, PN 1004120
Kit size: 10 rxns/kit
Description:
Pre-optimized kit and protocol for efficient brain tissue dissociation and myelin + RBC depletion with our LeviSelect technology.
- Start from as little as 10 mg of tissue
- Optimized to work with the LeviCell family of instruments
- Less than 2 hrs to assay-ready cells for single-cell profiling
Documents:




